{"product_id":"xray-cabinet","title":"X-Ray Cabinet for Industrial NDT","description":"\u003ch1 dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eCustom Industrial X-Ray Cabinets \u0026amp; NDT Enclosures\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 dir=\"auto\"\u003eHeavy-Duty Radiation Shielding Built Around Your Inspection Process\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eIndustrial X-ray inspection equipment demands more than an off-the-shelf shielding enclosure.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro designs and manufactures \u003cstrong\u003ecustom industrial X-ray cabinets, NDT enclosures and radiation-shielded inspection systems\u003c\/strong\u003e for applications ranging from individual component inspection to high-throughput production lines.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eWhether you already have completed engineering drawings or need an enclosure designed around your equipment and inspection process, we can provide a complete solution—from the structural cabinet and radiation shielding to doors, conveyors, equipment openings, controls integration and final installation.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eAvailable with lead shielding from 1\/16\" through 2\" thick.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eEvery enclosure is built around the actual requirements of the application rather than forcing your equipment into a predetermined cabinet size.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eHave Drawings? Send Us Your Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eNeed a Design? Let Us Engineer Your Enclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eBuilt for Industrial X-Ray and NDT Applications\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eIndustrial radiography is used to inspect the internal structure of components without cutting, disassembling or destroying them. Applications range from identifying defects in castings and welds to inspecting aerospace components, manufactured assemblies and critical structural parts.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eCabinet X-ray systems allow this inspection to take place within a radiation-shielded enclosure. FDA describes cabinet X-ray systems as systems that allow the interior of objects to be examined for manufacturing defects, contaminants and other internal characteristics without damaging the item being inspected. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eUnlike diagnostic medical X-ray rooms, industrial systems can involve significantly higher X-ray energies, larger components, longer exposure cycles and specialized material-handling equipment.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThat makes the enclosure part of the inspection system—not simply a box surrounding it.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro builds each cabinet around your:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eX-ray source and maximum operating energy\u003c\/li\u003e\n\u003cli\u003eRequired shielding thickness\u003c\/li\u003e\n\u003cli\u003ePart dimensions and weight\u003c\/li\u003e\n\u003cli\u003eSource-to-object and source-to-detector geometry\u003c\/li\u003e\n\u003cli\u003eInspection method\u003c\/li\u003e\n\u003cli\u003eProduction throughput\u003c\/li\u003e\n\u003cli\u003eMaterial-handling requirements\u003c\/li\u003e\n\u003cli\u003eDoor and access requirements\u003c\/li\u003e\n\u003cli\u003eEquipment mounting\u003c\/li\u003e\n\u003cli\u003eElectrical and control requirements\u003c\/li\u003e\n\u003cli\u003eFacility layout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eTwo Ways to Build Your Industrial X-Ray Cabinet\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eEvery project does not start at the same point.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eSome customers arrive with a complete set of approved fabrication drawings. Others have an X-ray generator, detector, part dimensions and production requirements but need the shielding enclosure developed around them.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro supports both.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eBuild to Your Drawings\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eAlready have an engineered design?\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eSend us your:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCAD drawings\u003c\/li\u003e\n\u003cli\u003eFabrication drawings\u003c\/li\u003e\n\u003cli\u003eShielding specifications\u003c\/li\u003e\n\u003cli\u003eLead thickness\u003c\/li\u003e\n\u003cli\u003eX-ray equipment specifications\u003c\/li\u003e\n\u003cli\u003eDoor requirements\u003c\/li\u003e\n\u003cli\u003eConveyor specifications\u003c\/li\u003e\n\u003cli\u003eStructural requirements\u003c\/li\u003e\n\u003cli\u003eElectrical and controls information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eWe can review the package and manufacture the enclosure to your approved specifications.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis is ideal for OEMs, engineering firms, NDT integrators and manufacturers that have already completed the system design.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eCustom Design \u0026amp; Fabrication\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eDon't have enclosure drawings?\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eProvide us with the requirements of the inspection system and we can develop the cabinet around the application.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eDepending on project scope, design inputs can include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eX-ray generator manufacturer and model\u003c\/li\u003e\n\u003cli\u003eMaximum kVp\u003c\/li\u003e\n\u003cli\u003eMaximum tube current\u003c\/li\u003e\n\u003cli\u003eBeam orientation\u003c\/li\u003e\n\u003cli\u003ePart dimensions\u003c\/li\u003e\n\u003cli\u003eMaximum part weight\u003c\/li\u003e\n\u003cli\u003eInspection geometry\u003c\/li\u003e\n\u003cli\u003eDetector or film arrangement\u003c\/li\u003e\n\u003cli\u003eRequired throughput\u003c\/li\u003e\n\u003cli\u003eMaterial handling method\u003c\/li\u003e\n\u003cli\u003eAvailable floor space\u003c\/li\u003e\n\u003cli\u003eRequired access\u003c\/li\u003e\n\u003cli\u003eShielding requirements\u003c\/li\u003e\n\u003cli\u003eFacility utilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe result is a purpose-built enclosure designed around how your inspection process actually operates.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eLead Shielding From 1\/16\" to 2\" Thick\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eIndustrial X-ray applications can require dramatically different levels of radiation shielding.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro manufactures custom industrial enclosures with lead shielding ranging from:\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003e1\/16\" • 1\/8\" • 1\/4\" • 3\/8\" • 1\/2\" • 3\/4\" • 1\" • 1-1\/2\" • up to 2\" thick lead\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIntermediate and application-specific configurations can also be manufactured.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe appropriate shielding is determined by the project's radiation shielding calculations and system requirements.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFactors affecting required shielding can include X-ray energy, tube current, workload, beam orientation, distance, enclosure geometry and occupancy surrounding the equipment.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFor this reason, Lead Glass Pro does not assume a standard lead thickness for industrial X-ray applications.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eWe build to the shielding requirement—not the other way around.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eA-Fab similarly notes that industrial cabinet shielding is determined by equipment energy, while NELCO describes optimizing enclosure shielding around the particular X-ray application. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eLead-and-Steel Cabinet Construction\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eIndustrial shielding has to do more than attenuate radiation.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIt also has to survive an industrial environment.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eOur cabinet systems can utilize \u003cstrong\u003esheet or plate lead mechanically contained within fabricated steel assemblies\u003c\/strong\u003e, creating a durable radiation barrier without leaving exposed lead surfaces.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eTypical construction can incorporate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStructural steel frame\u003c\/li\u003e\n\u003cli\u003eHeavy-gauge steel exterior panels\u003c\/li\u003e\n\u003cli\u003eInternal lead shielding\u003c\/li\u003e\n\u003cli\u003eSteel interior surfaces\u003c\/li\u003e\n\u003cli\u003eShielded structural seams\u003c\/li\u003e\n\u003cli\u003eReinforced equipment openings\u003c\/li\u003e\n\u003cli\u003eHeavy-duty base structure\u003c\/li\u003e\n\u003cli\u003ePowder-coated or industrial painted finish\u003c\/li\u003e\n\u003cli\u003eForklift or rigging provisions where appropriate\u003c\/li\u003e\n\u003cli\u003eServiceable access panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe structural design can be scaled to accommodate the substantial weight associated with heavy shielding.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFor reference, A-Fab describes its industrial X-ray cabinets as lead sandwiched between steel panels over a structural frame. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eWith Lead Glass Pro systems available up to \u003cstrong\u003e2\" of lead\u003c\/strong\u003e, structural support becomes an integral part of the enclosure design rather than an afterthought.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eConveyorized X-Ray Inspection Cabinets\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eFor production inspection, the cabinet can become part of the manufacturing line.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro can design enclosures around:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoller conveyors\u003c\/li\u003e\n\u003cli\u003ePowered belt conveyors\u003c\/li\u003e\n\u003cli\u003eChain conveyors\u003c\/li\u003e\n\u003cli\u003ePallet conveyors\u003c\/li\u003e\n\u003cli\u003eCustom material-handling systems\u003c\/li\u003e\n\u003cli\u003eAutomated loading systems\u003c\/li\u003e\n\u003cli\u003eRobotic loading and unloading\u003c\/li\u003e\n\u003cli\u003ePass-through production lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eConveyor height, opening size and cabinet dimensions can be designed around your existing production equipment.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eNELCO similarly identifies conveyor systems, robotic automation, overhead cranes and other material-handling systems as important design considerations for industrial radiation shielding. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eShielded Conveyor Openings\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eA conveyor passing through an X-ray cabinet creates one of the most important shielding challenges in the system.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe opening must allow the product to enter and exit while controlling radiation through the penetration.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eDepending on the application, the design may incorporate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShielded tunnels\u003c\/li\u003e\n\u003cli\u003eExtended entrance and exit sections\u003c\/li\u003e\n\u003cli\u003eInternal shielding baffles\u003c\/li\u003e\n\u003cli\u003eLead curtains\u003c\/li\u003e\n\u003cli\u003eOffset radiation paths\u003c\/li\u003e\n\u003cli\u003eCollimation\u003c\/li\u003e\n\u003cli\u003eRestricted aperture geometry\u003c\/li\u003e\n\u003cli\u003eInterlocked product-access systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe appropriate solution depends on equipment energy, beam orientation, part dimensions and required throughput.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFor cabinet X-ray systems subject to 21 CFR 1020.40, ports and apertures are specifically addressed by the federal performance standard, including protection against access to the primary beam. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eManual, Pneumatic and Powered Door Systems\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eNot every application requires a conveyor.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFor batch inspection, oversized components or manual loading, Lead Glass Pro can manufacture cabinet systems with a variety of shielded access configurations.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eOptions can include:\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eManual Hinged Doors\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eA straightforward solution for smaller components and lower-cycle applications.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eSliding Shielded Doors\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eIdeal where swing clearance is limited or where larger openings are required.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003ePneumatic Doors\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eDesigned for repetitive production environments where faster loading and unloading are important.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eMotorized Doors\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003ePowered door systems can be integrated into automated inspection processes.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eMultiple-Door Systems\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eCabinets can incorporate separate loading, unloading, service or maintenance doors.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eDoor shielding is designed to maintain continuity with the surrounding cabinet barrier.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eA-Fab similarly offers manually operated, pneumatic and motor-operated doors, including multiple-door configurations for production systems. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eSafety Interlocks\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eA properly designed industrial X-ray enclosure requires more than physical shielding.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eDoors and access points can be integrated with safety interlocks so X-ray generation is prevented or terminated when required access conditions are not satisfied.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFor systems classified as cabinet X-ray systems under 21 CFR 1020.40, FDA requires each door to incorporate at least two safety interlocks, with specific requirements governing their operation. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eDepending on system scope, Lead Glass Pro enclosures can accommodate integration of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual door interlocks\u003c\/li\u003e\n\u003cli\u003ePosition switches\u003c\/li\u003e\n\u003cli\u003eSafety-rated switches\u003c\/li\u003e\n\u003cli\u003eEmergency-stop circuits\u003c\/li\u003e\n\u003cli\u003eX-ray enable circuits\u003c\/li\u003e\n\u003cli\u003eAccess-panel monitoring\u003c\/li\u003e\n\u003cli\u003eConveyor safety controls\u003c\/li\u003e\n\u003cli\u003eExternal equipment interlocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eFinal safety architecture is coordinated with the X-ray equipment and system-control design.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eX-Ray Warning Lights and Status Indicators\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eThe enclosure can incorporate highly visible machine-status indicators such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eX-RAY ON indicators\u003c\/li\u003e\n\u003cli\u003eMain power indicators\u003c\/li\u003e\n\u003cli\u003eRed\/amber\/green stack lights\u003c\/li\u003e\n\u003cli\u003eAudible warnings\u003c\/li\u003e\n\u003cli\u003eDoor status indicators\u003c\/li\u003e\n\u003cli\u003eSystem-ready indicators\u003c\/li\u003e\n\u003cli\u003eEmergency-stop stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eCabinet X-ray systems regulated under the federal performance standard have specific requirements for warning lights, warning labels and other safety features. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eIntegrated Control Stations\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eInstead of adding controls to the enclosure after fabrication, the cabinet can be designed around the system controls from the beginning.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eOptions can include mounting provisions for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHMI touchscreen\u003c\/li\u003e\n\u003cli\u003ePLC controls\u003c\/li\u003e\n\u003cli\u003eX-ray generator controls\u003c\/li\u003e\n\u003cli\u003eEmergency stop\u003c\/li\u003e\n\u003cli\u003eConveyor controls\u003c\/li\u003e\n\u003cli\u003eStatus indicators\u003c\/li\u003e\n\u003cli\u003eKey switches\u003c\/li\u003e\n\u003cli\u003eIndustrial PC\u003c\/li\u003e\n\u003cli\u003eImage-review monitor\u003c\/li\u003e\n\u003cli\u003eControl cabinet\u003c\/li\u003e\n\u003cli\u003eNetwork hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThis creates a cleaner installation and helps protect the shielding barrier from unnecessary field modifications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eX-Ray Generator and Detector Integration\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eThe enclosure can be fabricated around your existing imaging hardware.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eMounting provisions can be incorporated for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eX-ray tubes\u003c\/li\u003e\n\u003cli\u003eX-ray generators\u003c\/li\u003e\n\u003cli\u003eFlat-panel detectors\u003c\/li\u003e\n\u003cli\u003eLinear detector arrays\u003c\/li\u003e\n\u003cli\u003eDigital radiography systems\u003c\/li\u003e\n\u003cli\u003eFilm radiography\u003c\/li\u003e\n\u003cli\u003eManipulators\u003c\/li\u003e\n\u003cli\u003eTurntables\u003c\/li\u003e\n\u003cli\u003ePositioning fixtures\u003c\/li\u003e\n\u003cli\u003eMotorized axes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eService access can be incorporated where equipment requires routine maintenance or replacement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eCustom Part Positioning and Manipulation\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eSeeing inside a part is only useful if the part and imaging equipment can be positioned correctly.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eCustom cabinets can incorporate or accommodate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePowered turntables\u003c\/li\u003e\n\u003cli\u003eManual turntables\u003c\/li\u003e\n\u003cli\u003eLinear stages\u003c\/li\u003e\n\u003cli\u003eLift tables\u003c\/li\u003e\n\u003cli\u003eRotary fixtures\u003c\/li\u003e\n\u003cli\u003ePart manipulators\u003c\/li\u003e\n\u003cli\u003eDetector positioning systems\u003c\/li\u003e\n\u003cli\u003eSource positioning systems\u003c\/li\u003e\n\u003cli\u003eRobotic systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eCabinet dimensions are then established around the required inspection envelope rather than simply around the physical size of the component.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eIndustrial CT Enclosures\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro can also manufacture shielding enclosures for \u003cstrong\u003eindustrial computed tomography and CT inspection equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIndustrial CT systems may require additional consideration for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRotating parts\u003c\/li\u003e\n\u003cli\u003eMultiple projection angles\u003c\/li\u003e\n\u003cli\u003eDetector travel\u003c\/li\u003e\n\u003cli\u003eSource movement\u003c\/li\u003e\n\u003cli\u003eHigh inspection workloads\u003c\/li\u003e\n\u003cli\u003ePrecision positioning equipment\u003c\/li\u003e\n\u003cli\u003eEquipment vibration\u003c\/li\u003e\n\u003cli\u003eService clearances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe shielding enclosure can be developed around the equipment manufacturer's geometry and shielding requirements.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eNELCO likewise identifies industrial CT as an application for its custom X-ray cabinets and imaging enclosures. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eOversized Industrial X-Ray Cabinets\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eNot every cabinet belongs on a tabletop.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro can manufacture larger systems for parts that require:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eForklift loading\u003c\/li\u003e\n\u003cli\u003eCrane loading\u003c\/li\u003e\n\u003cli\u003ePallet loading\u003c\/li\u003e\n\u003cli\u003eRobotic handling\u003c\/li\u003e\n\u003cli\u003eLarge fixtures\u003c\/li\u003e\n\u003cli\u003eOversized inspection envelopes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eWhen an application becomes large enough for personnel or machinery to enter the enclosure, a walk-in industrial X-ray room or NDT vault may be more appropriate than a cabinet.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro also supplies shielding systems for those applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eApplications for Industrial X-Ray Cabinets\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eCustom X-ray inspection enclosures can be designed for:\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eAerospace\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eInspection of castings, turbine components, structural components, welds and other critical aerospace parts.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eAutomotive\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eInspection of castings, welds, batteries, assemblies and manufactured components.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eFoundries and Casting\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eIdentification of internal porosity, inclusions, voids, cracks and other casting defects.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWeld Inspection\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eNon-destructive radiographic examination of welded assemblies and fabricated components.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eAdditive Manufacturing\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eInspection of complex 3D-printed metal components for internal defects that cannot be detected visually.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eElectronics\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eInspection of assemblies, connectors, solder joints, components and internal construction.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eEnergy\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eInspection of valves, piping components, weldments and other critical equipment.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eDefense\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eRadiographic inspection of manufactured components and assemblies subject to project-specific requirements.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eResearch and Development\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eCustom shielding enclosures for laboratories, universities, materials research and prototype imaging equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eDesigned for NDT Radiography\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eIndustrial radiographic examination is widely used for non-destructive evaluation of metallic and nonmetallic materials.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eASTM E1742 establishes basic parameters for controlling radiographic examination and is intended to be supplemented by application-specific procedures and requirements. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro can manufacture the shielding enclosure around the NDT process specified by the customer's engineering, quality and radiation-safety teams.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eCabinet X-Ray System Compliance\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eWhen the completed equipment meets the definition of a \u003cstrong\u003ecabinet X-ray system\u003c\/strong\u003e, federal requirements may apply to the finished system.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFDA's cabinet X-ray performance standard is contained in \u003cstrong\u003e21 CFR 1020.40\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAmong other requirements, the standard limits radiation emitted from a cabinet X-ray system to \u003cstrong\u003e0.5 milliroentgen in one hour measured 5 cm from the external surface\u003c\/strong\u003e under the prescribed test conditions. It also establishes requirements for features including doors, interlocks, indicators, warning labels, ports, apertures and instructions. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro can manufacture shielding enclosures around customer and system-integrator specifications.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eResponsibility for certification and regulatory compliance of the \u003cstrong\u003ecomplete X-ray-generating system\u003c\/strong\u003e should be established as part of the project scope when the enclosure is integrated with X-ray-generating equipment.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThat distinction is important for OEM and custom equipment projects.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eDesigned for Serviceability\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eIndustrial equipment eventually needs maintenance.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eA cabinet should not have to be dismantled simply to service an X-ray tube, detector, motor or cable.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eCustom designs can incorporate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShielded removable panels\u003c\/li\u003e\n\u003cli\u003eInterlocked access panels\u003c\/li\u003e\n\u003cli\u003eEquipment service doors\u003c\/li\u003e\n\u003cli\u003eRemovable interior panels\u003c\/li\u003e\n\u003cli\u003eCable access\u003c\/li\u003e\n\u003cli\u003eReplaceable lead curtains\u003c\/li\u003e\n\u003cli\u003eGenerator access\u003c\/li\u003e\n\u003cli\u003eControl cabinet access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThese features can be incorporated without unnecessarily compromising the shielding envelope.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eClean, Professional Industrial Construction\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eHeavy-duty does not have to mean unfinished.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro industrial X-ray cabinets can be manufactured with a professional finished appearance suitable for modern manufacturing, aerospace, laboratory and quality-control environments.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAvailable features can include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePowder-coated steel\u003c\/li\u003e\n\u003cli\u003eCustom colors\u003c\/li\u003e\n\u003cli\u003eConcealed wiring\u003c\/li\u003e\n\u003cli\u003eIntegrated control cabinets\u003c\/li\u003e\n\u003cli\u003eFlush access panels\u003c\/li\u003e\n\u003cli\u003eClean panel transitions\u003c\/li\u003e\n\u003cli\u003eFinished trim\u003c\/li\u003e\n\u003cli\u003eIntegrated warning lights\u003c\/li\u003e\n\u003cli\u003eMachine identification and labeling\u003c\/li\u003e\n\u003cli\u003eStainless steel components where appropriate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe result is an enclosure that looks like a purpose-built piece of industrial equipment rather than shielding added around one after the fact.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eFrom Concept to Finished Enclosure\u003c\/h1\u003e\n\u003ch2 dir=\"auto\"\u003e1. Define the Application\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eSend us your existing drawings or provide the requirements for the inspection process.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e2. Establish Shielding Requirements\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe specified shielding requirement is incorporated into the enclosure design. Lead shielding is available from \u003cstrong\u003e1\/16\" through 2\" thick\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e3. Develop the Cabinet\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eDimensions, structure, doors, conveyors, equipment interfaces, service access and penetrations are coordinated into the enclosure.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e4. Review Drawings\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eProject drawings can be submitted for customer review and approval before fabrication.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e5. Fabrication\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe structural frame, lead shielding, steel panels, doors and other enclosure components are manufactured as a coordinated system.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e6. Integration\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eDepending on project scope, provisions for conveyors, controls, interlocks, equipment mounting and other components are incorporated.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e7. Installation\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro can provide professional installation for custom radiation shielding systems throughout the United States. Our existing installation capabilities include complete radiation-shielding coordination and nationwide service. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eWhy Lead Glass Pro?\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eAn industrial X-ray cabinet brings together several disciplines:\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eRadiation shielding.\u003cbr\u003eStructural fabrication.\u003cbr\u003eDoors.\u003cbr\u003eEquipment openings.\u003cbr\u003eMaterial handling.\u003cbr\u003eElectrical interfaces.\u003cbr\u003eSafety systems.\u003cbr\u003eInstallation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro already specializes in high-performance radiation shielding for industrial NDT applications, including sheet and plate lead, lead-lined doors and frames, radiation-shielded windows, custom shielding components and complete installations. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eInstead of treating the enclosure as a collection of unrelated components, we approach it as a complete radiation shielding system.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eHeavy Shielding Capability\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eCustom configurations available from \u003cstrong\u003e1\/16\" through 2\" thick lead\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eCustom Fabrication\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eCabinets are built around your equipment, components and process.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eBuild to Print\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eSend us your completed drawings and specifications.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eDesign Assistance\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eDon't have enclosure drawings? We can develop a custom solution around your application.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eComplete Systems\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eDoors, shielding, structural enclosure, penetrations, equipment interfaces and installation can be coordinated through one supplier.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eNationwide Installation\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eProfessional radiation shielding installation is available throughout the United States. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eFrequently Asked Questions About Industrial X-Ray Cabinets\u003c\/h1\u003e\n\u003ch2 dir=\"auto\"\u003eWhat is an industrial X-ray cabinet?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eAn industrial X-ray cabinet is a radiation-shielded enclosure used to inspect parts, assemblies or materials with X-rays while limiting radiation outside the enclosure. Systems can range from small manually loaded cabinets to large conveyorized inspection systems.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eWhat are industrial X-ray cabinets used for?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThey are commonly used for non-destructive testing and quality inspection of castings, welds, aerospace components, automotive parts, electronics, additive-manufactured parts and other components where internal defects or features must be examined without destroying the part.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eHow thick is the lead in an industrial X-ray cabinet?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThere is no universal lead thickness. Shielding depends on X-ray energy, workload, beam orientation, cabinet geometry and other application-specific factors.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eLead Glass Pro can manufacture custom industrial X-ray cabinets with \u003cstrong\u003elead shielding from 1\/16\" through 2\" thick\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eCan you build an X-ray cabinet from our drawings?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eYes. Lead Glass Pro can fabricate custom industrial X-ray shielding enclosures from customer-supplied drawings and specifications.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eSend us your drawings, required lead thickness, equipment specifications and project requirements for review.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eCan Lead Glass Pro design the cabinet for us?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eYes. If you do not already have enclosure drawings, we can work from your equipment specifications, inspection requirements, part dimensions, shielding requirements and facility constraints to develop a custom enclosure.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eCan you build conveyorized X-ray cabinets?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eYes. Cabinets can be designed around roller, belt, pallet and other conveyor systems, including custom entrance and exit shielding configurations.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eCan you build an enclosure around our existing X-ray equipment?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eYes. Custom cabinets can be designed around customer-supplied X-ray generators, tubes, detectors and positioning equipment.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eDo you manufacture cabinets for industrial CT?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eCustom shielding enclosures can be manufactured for industrial CT and digital radiography equipment when provided with the appropriate equipment geometry and shielding requirements.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eCan you build an X-ray cabinet with 1\" or 2\" lead?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eYes. Lead Glass Pro offers industrial shielding configurations from \u003cstrong\u003e1\/16\" up to 2\" thick lead\u003c\/strong\u003e, subject to structural and project-specific design requirements.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eCan the cabinet have automatic doors?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eYes. Depending on the application, cabinets can incorporate manual, pneumatic or motorized access systems.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eCan you incorporate safety interlocks?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eCabinets can be designed with provisions for safety interlocks and integration with the X-ray equipment control system. Applicable requirements depend on the completed system and its regulatory classification.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eDo you install industrial X-ray cabinets?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eYes. Lead Glass Pro provides nationwide radiation shielding installation services. Installation scope can be coordinated with the size, weight and complexity of the enclosure.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eDo industrial X-ray cabinets have to comply with FDA requirements?\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eCabinet X-ray systems subject to \u003cstrong\u003e21 CFR 1020.40\u003c\/strong\u003e must meet the applicable federal radiation safety performance requirements. The regulatory responsibilities for a custom project depend on the scope of the complete X-ray system and which party manufactures or assembles the radiation-emitting product. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1 dir=\"auto\"\u003eRequest a Custom Industrial X-Ray Cabinet Quote\u003c\/h1\u003e\n\u003cp dir=\"auto\"\u003eWhether you already have a complete drawing package or are starting with an X-ray source and a part that needs to be inspected, Lead Glass Pro can help develop the shielding enclosure around your application.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eAlready Have Drawings?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eSend us your: \u003cstrong\u003eDrawings • Lead Thickness • Equipment Specifications • Cabinet Dimensions • Door Requirements • Conveyor Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eWe'll review the project for custom fabrication.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eNeed Us to Design It?\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eSend us: \u003cstrong\u003eX-Ray Equipment • Lead Thickness • Maximum kVp • Part Size \u0026amp; Weight • Inspection Method • Shielding Requirements • Desired Throughput • Available Space\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eWe'll use those requirements to begin developing the enclosure.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eCustom Industrial X-Ray Shielding — From 1\/16\" to 2\" Lead\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eUpload Your Drawings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eTalk to an Industrial Shielding Specialist\u003c\/strong\u003e\u003c\/p\u003e","brand":"Lead Glass Pro","offers":[{"title":"Default Title","offer_id":54128931143864,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/7202\/8986\/files\/Industrial_NDT_X-Ray_Cabinet_3.png?v=1789736280","url":"https:\/\/leadglasspro.com\/products\/xray-cabinet","provider":"Lead Glass Pro","version":"1.0","type":"link"}