{"product_id":"modular-x-ray-room","title":"Modular X-Ray Room | Prefabricated Radiation Shielding Room","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eA Complete, Factory-Built Radiation Shielding Room\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eLead Glass Pro modular X-ray rooms provide a premium alternative to constructing a radiation-shielded room piece by piece in the field.\u003c\/p\u003e\n\u003cp\u003eEach room is designed as a \u003cstrong\u003ecomplete, integrated shielding system\u003c\/strong\u003e built around the requirements of your radiation shielding report. Walls, ceiling, doors, viewing windows, electrical provisions, equipment penetrations, ventilation interfaces and architectural finishes are coordinated into one modular system.\u003c\/p\u003e\n\u003cp\u003eThe result is a professional imaging room that installs faster, looks better and eliminates many of the coordination problems that occur when multiple trades are responsible for different portions of the radiation barrier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis is not simply a collection of shielded wall panels. It is a complete room system engineered, fabricated and installed as one package.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eBuilt for Projects Where Quality Matters\u003c\/h1\u003e\n\u003cp\u003eMany modular shielding rooms are designed primarily around function.\u003c\/p\u003e\n\u003cp\u003eOurs is designed around \u003cstrong\u003efunction, appearance, installation and long-term serviceability.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery Lead Glass Pro modular X-ray room is engineered to provide the shielding required by your project while maintaining the appearance expected in a modern medical, imaging, laboratory or industrial facility.\u003c\/p\u003e\n\u003cp\u003eInstead of exposed wiring, surface-mounted conduit and unfinished utility penetrations, our premium room system can incorporate concealed electrical pathways, integrated service areas and factory-designed penetrations.\u003c\/p\u003e\n\u003cp\u003eThe goal is simple:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA modular radiation shielding room that looks and performs like a permanent, professionally constructed space.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eRadiation Shielding Built to Your Shielding Report\u003c\/h1\u003e\n\u003cp\u003eRadiation shielding requirements are not one-size-fits-all.\u003c\/p\u003e\n\u003cp\u003eLead thickness and shielding locations should be determined by a qualified radiation physicist or shielding designer based on factors such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eX-ray equipment type\u003c\/li\u003e\n\u003cli\u003eEquipment workload\u003c\/li\u003e\n\u003cli\u003eOperating kVp\u003c\/li\u003e\n\u003cli\u003eRoom layout\u003c\/li\u003e\n\u003cli\u003eEquipment orientation\u003c\/li\u003e\n\u003cli\u003eAdjacent occupancy\u003c\/li\u003e\n\u003cli\u003eDistance from the radiation source\u003c\/li\u003e\n\u003cli\u003eWall construction\u003c\/li\u003e\n\u003cli\u003eFloor and ceiling conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLead Glass Pro manufactures each modular X-ray room according to the shielding requirements provided for the project.\u003c\/p\u003e\n\u003cp\u003eAvailable shielding can include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShielded walls\u003c\/li\u003e\n\u003cli\u003eShielded ceiling\u003c\/li\u003e\n\u003cli\u003eShielded floor\u003c\/li\u003e\n\u003cli\u003eLead-lined doors\u003c\/li\u003e\n\u003cli\u003eLead-lined door frames\u003c\/li\u003e\n\u003cli\u003eLead glass viewing windows\u003c\/li\u003e\n\u003cli\u003eShielded electrical penetrations\u003c\/li\u003e\n\u003cli\u003eShielded equipment cable penetrations\u003c\/li\u003e\n\u003cli\u003eShielded HVAC penetrations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDifferent barriers within the same room can also be manufactured with different lead equivalencies when required by the shielding report.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMore Than a Modular X-Ray Booth\u003c\/h1\u003e\n\u003cp\u003eOur modular rooms are intended for customers who want a finished facility—not an industrial enclosure dropped into a building.\u003c\/p\u003e\n\u003cp\u003eA complete system can include:\u003c\/p\u003e\n\u003ch3\u003eModular Shielded Wall System\u003c\/h3\u003e\n\u003cp\u003eFactory-manufactured wall assemblies incorporate the required radiation shielding within a durable structural system.\u003c\/p\u003e\n\u003cp\u003eArchitectural interior and exterior finishes create a clean, professional appearance while allowing the room to be disassembled or reconfigured when the application permits.\u003c\/p\u003e\n\u003ch3\u003eConcealed Utility Integration\u003c\/h3\u003e\n\u003cp\u003eElectrical wiring, low-voltage wiring, controls and other services can be routed within designated service areas rather than installed across the finished wall surface.\u003c\/p\u003e\n\u003cp\u003eThis allows the interior to remain clean while helping protect the integrity of the radiation barrier.\u003c\/p\u003e\n\u003ch3\u003eFinished Modular Ceiling\u003c\/h3\u003e\n\u003cp\u003eEvery room can incorporate a finished ceiling system regardless of whether radiation shielding is required overhead.\u003c\/p\u003e\n\u003cp\u003eWhen ceiling shielding is required, the necessary lead equivalency is incorporated into the ceiling assembly.\u003c\/p\u003e\n\u003cp\u003eLighting, ventilation and other ceiling components can be coordinated into the modular system.\u003c\/p\u003e\n\u003ch3\u003eLead-Lined Door and Frame\u003c\/h3\u003e\n\u003cp\u003eOur lead-lined door assemblies are manufactured as part of the complete shielding package.\u003c\/p\u003e\n\u003cp\u003eAvailable configurations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSingle swing doors\u003c\/li\u003e\n\u003cli\u003eDouble doors\u003c\/li\u003e\n\u003cli\u003eSliding doors\u003c\/li\u003e\n\u003cli\u003eAutomatic sliding doors\u003c\/li\u003e\n\u003cli\u003eHollow metal doors\u003c\/li\u003e\n\u003cli\u003eWood doors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDoor shielding is manufactured to the project requirements.\u003c\/p\u003e\n\u003ch3\u003eLead Glass Viewing Window\u003c\/h3\u003e\n\u003cp\u003eLead Glass Pro manufactures and supplies radiation-shielded viewing windows using lead glass selected for the shielding requirements of the room.\u003c\/p\u003e\n\u003cp\u003eWindow size, location and configuration can be customized around the equipment layout and operator requirements.\u003c\/p\u003e\n\u003ch3\u003eFinished Flooring\u003c\/h3\u003e\n\u003cp\u003eThe room can be supplied with a completed flooring system for a more turnkey installation.\u003c\/p\u003e\n\u003cp\u003eWhen floor shielding is required, sheet lead can be incorporated beneath the finished flooring with proper overlap into adjacent shielding assemblies.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eIntegrated Shielded Service Areas\u003c\/h1\u003e\n\u003cp\u003eOne of the most important elements of a radiation shielding room is what happens \u003cstrong\u003eafter the walls are installed\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectrical contractors, equipment installers, HVAC contractors and low-voltage installers frequently need to pass services through the room.\u003c\/p\u003e\n\u003cp\u003eImproper penetrations can compromise an otherwise correctly constructed radiation barrier.\u003c\/p\u003e\n\u003cp\u003eOur modular room system can incorporate dedicated service areas for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical receptacles\u003c\/li\u003e\n\u003cli\u003eData connections\u003c\/li\u003e\n\u003cli\u003eEquipment controls\u003c\/li\u003e\n\u003cli\u003eX-ray warning lights\u003c\/li\u003e\n\u003cli\u003eDoor interlocks\u003c\/li\u003e\n\u003cli\u003eEmergency-stop circuits\u003c\/li\u003e\n\u003cli\u003eImaging equipment cables\u003c\/li\u003e\n\u003cli\u003eNetwork cabling\u003c\/li\u003e\n\u003cli\u003eFuture equipment connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy planning these services during manufacturing, the room can accommodate equipment without unnecessary field modifications to the shielding system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFactory-Designed Shielded Penetrations\u003c\/h1\u003e\n\u003cp\u003eAny opening through a radiation barrier should be considered part of the shielding design.\u003c\/p\u003e\n\u003cp\u003eLead Glass Pro can incorporate factory-designed penetration assemblies for:\u003c\/p\u003e\n\u003ch3\u003eEquipment Cables\u003c\/h3\u003e\n\u003cp\u003eShielded cable-pass-through assemblies allow imaging equipment cables to enter or exit the room without creating a direct radiation path.\u003c\/p\u003e\n\u003ch3\u003eElectrical Services\u003c\/h3\u003e\n\u003cp\u003eElectrical boxes and service locations can be shielded as part of the room assembly rather than being cut into the barrier after installation.\u003c\/p\u003e\n\u003ch3\u003eHVAC and Ventilation\u003c\/h3\u003e\n\u003cp\u003eVentilation openings can incorporate shielded offset or baffled configurations when required by the shielding design.\u003c\/p\u003e\n\u003ch3\u003ePlumbing and Other Utilities\u003c\/h3\u003e\n\u003cp\u003eAdditional project-specific penetrations can be reviewed and incorporated before manufacturing begins.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eDesigned Before It Arrives at Your Facility\u003c\/h1\u003e\n\u003cp\u003eA premium modular room should not be figured out on the jobsite.\u003c\/p\u003e\n\u003cp\u003eBefore production, the room layout is coordinated around factors such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverall room dimensions\u003c\/li\u003e\n\u003cli\u003eEquipment footprint\u003c\/li\u003e\n\u003cli\u003eDoor location\u003c\/li\u003e\n\u003cli\u003eWindow location\u003c\/li\u003e\n\u003cli\u003eShielding requirements\u003c\/li\u003e\n\u003cli\u003eElectrical requirements\u003c\/li\u003e\n\u003cli\u003eHVAC requirements\u003c\/li\u003e\n\u003cli\u003eEquipment penetrations\u003c\/li\u003e\n\u003cli\u003eCeiling requirements\u003c\/li\u003e\n\u003cli\u003eFloor shielding\u003c\/li\u003e\n\u003cli\u003eInstallation access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMajor components can be fabricated and checked before shipment so the field installation follows a predetermined layout.\u003c\/p\u003e\n\u003cp\u003eIndividual room components can also be identified and coordinated with installation drawings to simplify assembly at the project site.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFaster Installation With Less Field Construction\u003c\/h1\u003e\n\u003cp\u003eTraditional X-ray room construction can require coordination between:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral contractors\u003c\/li\u003e\n\u003cli\u003eFramers\u003c\/li\u003e\n\u003cli\u003eDrywall installers\u003c\/li\u003e\n\u003cli\u003eRadiation shielding installers\u003c\/li\u003e\n\u003cli\u003eElectricians\u003c\/li\u003e\n\u003cli\u003eHVAC contractors\u003c\/li\u003e\n\u003cli\u003eDoor installers\u003c\/li\u003e\n\u003cli\u003eGlass installers\u003c\/li\u003e\n\u003cli\u003eFlooring contractors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEvery transition between trades creates another opportunity for delays, damaged shielding or improperly treated penetrations.\u003c\/p\u003e\n\u003cp\u003eA modular X-ray room consolidates much of that work into a factory-manufactured system.\u003c\/p\u003e\n\u003cp\u003eDepending on project size and site conditions, this can significantly reduce the amount of construction required at the facility.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eProfessional Installation Available Nationwide\u003c\/h1\u003e\n\u003cp\u003eLead Glass Pro can provide professional installation for modular radiation shielding rooms throughout the United States.\u003c\/p\u003e\n\u003cp\u003eOur radiation shielding installation teams understand the details that matter, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShielding continuity\u003c\/li\u003e\n\u003cli\u003ePanel overlaps\u003c\/li\u003e\n\u003cli\u003eCorners\u003c\/li\u003e\n\u003cli\u003eDoor transitions\u003c\/li\u003e\n\u003cli\u003eWindow transitions\u003c\/li\u003e\n\u003cli\u003eCeiling intersections\u003c\/li\u003e\n\u003cli\u003eFloor-to-wall transitions\u003c\/li\u003e\n\u003cli\u003eElectrical boxes\u003c\/li\u003e\n\u003cli\u003eEquipment penetrations\u003c\/li\u003e\n\u003cli\u003eHVAC penetrations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHaving the room supplied and installed by the same company reduces uncertainty about who is responsible for the finished shielding system.\u003c\/p\u003e\n\u003cp\u003eOur installation work is backed by our \u003cstrong\u003e10-year installation warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003ePremium Interior and Exterior Finishes\u003c\/h1\u003e\n\u003cp\u003eA modular room does not have to look temporary.\u003c\/p\u003e\n\u003cp\u003eAvailable finishes can be selected around the environment where the room will be installed.\u003c\/p\u003e\n\u003cp\u003eOptions may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePowder-coated metal\u003c\/li\u003e\n\u003cli\u003eArchitectural metal panels\u003c\/li\u003e\n\u003cli\u003eHigh-pressure laminate\u003c\/li\u003e\n\u003cli\u003eHealthcare wall panels\u003c\/li\u003e\n\u003cli\u003eDurable polymer wall systems\u003c\/li\u003e\n\u003cli\u003eCustom colors\u003c\/li\u003e\n\u003cli\u003eStainless steel accents\u003c\/li\u003e\n\u003cli\u003eCommercial flooring\u003c\/li\u003e\n\u003cli\u003eHealthcare sheet flooring with integral cove\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe result can range from a clean industrial enclosure to a high-end medical imaging suite.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eModular Without Looking Temporary\u003c\/h1\u003e\n\u003cp\u003eOne of the biggest advantages of modular construction is flexibility.\u003c\/p\u003e\n\u003cp\u003eDepending on the room configuration, the system may be:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstalled inside an existing facility\u003c\/li\u003e\n\u003cli\u003eRemoved later\u003c\/li\u003e\n\u003cli\u003eRelocated\u003c\/li\u003e\n\u003cli\u003eModified\u003c\/li\u003e\n\u003cli\u003eExpanded\u003c\/li\u003e\n\u003cli\u003eReconfigured for different equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThat flexibility does not require sacrificing the appearance of a permanent room.\u003c\/p\u003e\n\u003cp\u003eThe modular connections, shielding transitions and service systems are designed to remain largely concealed within the finished assembly.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eApplications\u003c\/h1\u003e\n\u003cp\u003eLead Glass Pro modular radiation shielding rooms can be designed for applications including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostic X-ray\u003c\/li\u003e\n\u003cli\u003eDigital radiography\u003c\/li\u003e\n\u003cli\u003eChiropractic X-ray\u003c\/li\u003e\n\u003cli\u003eVeterinary X-ray\u003c\/li\u003e\n\u003cli\u003eDental imaging\u003c\/li\u003e\n\u003cli\u003eCBCT\u003c\/li\u003e\n\u003cli\u003eC-arm imaging\u003c\/li\u003e\n\u003cli\u003eMobile imaging facilities\u003c\/li\u003e\n\u003cli\u003eResearch laboratories\u003c\/li\u003e\n\u003cli\u003eIndustrial radiography\u003c\/li\u003e\n\u003cli\u003eNondestructive testing\u003c\/li\u003e\n\u003cli\u003eManufacturing inspection\u003c\/li\u003e\n\u003cli\u003eSecurity inspection\u003c\/li\u003e\n\u003cli\u003eTemporary imaging facilities\u003c\/li\u003e\n\u003cli\u003eEquipment demonstration facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHigher-energy applications may require specialized engineering and significantly heavier shielding assemblies.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eStandard and Custom Room Sizes\u003c\/h1\u003e\n\u003cp\u003eRooms can be manufactured around the space available and the imaging equipment being installed.\u003c\/p\u003e\n\u003cp\u003eTypical configurations may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8' × 8'\u003c\/li\u003e\n\u003cli\u003e8' × 10'\u003c\/li\u003e\n\u003cli\u003e10' × 10'\u003c\/li\u003e\n\u003cli\u003e10' × 12'\u003c\/li\u003e\n\u003cli\u003e12' × 12'\u003c\/li\u003e\n\u003cli\u003e12' × 16'\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLarger and completely custom rooms are also available.\u003c\/p\u003e\n\u003cp\u003eDoor locations, windows, utilities and penetrations can be positioned around the project layout rather than forcing the imaging equipment to fit a predetermined enclosure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eA Complete X-Ray Room From One Company\u003c\/h1\u003e\n\u003cp\u003eThe greatest advantage of the Lead Glass Pro modular room system is not any single component.\u003c\/p\u003e\n\u003cp\u003eIt is the ability to provide the entire shielding package through one company.\u003c\/p\u003e\n\u003cp\u003eA project can include:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation shielding\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eModular wall system\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded ceiling\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eLead-lined doors and frames\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eLead glass viewing windows\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eElectrical shielding\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCable penetrations\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eHVAC shielding\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eFinished flooring\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstead of purchasing individual shielding components and asking a general contractor to coordinate them, Lead Glass Pro can provide a complete system designed to work together.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eBuilt for the Finished Result\u003c\/h1\u003e\n\u003cp\u003eRadiation shielding is ultimately judged by what happens when the room is complete.\u003c\/p\u003e\n\u003cp\u003eA beautiful imaging room that does not meet the shielding design is a failed project.\u003c\/p\u003e\n\u003cp\u003eA room that provides shielding but is difficult to wire, difficult to service or poorly finished creates another set of problems.\u003c\/p\u003e\n\u003cp\u003eOur modular X-ray rooms are designed around both.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCorrect shielding. Clean installation. Professional appearance. One complete system.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhy Lead Glass Pro?\u003c\/h1\u003e\n\u003cp\u003eLead Glass Pro specializes in radiation shielding products and complete shielding systems.\u003c\/p\u003e\n\u003cp\u003eOur capabilities include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLead glass\u003c\/li\u003e\n\u003cli\u003eX-ray windows\u003c\/li\u003e\n\u003cli\u003eLead-lined doors\u003c\/li\u003e\n\u003cli\u003eLead-lined frames\u003c\/li\u003e\n\u003cli\u003eLead-backed drywall\u003c\/li\u003e\n\u003cli\u003eSheet lead\u003c\/li\u003e\n\u003cli\u003eShielded electrical backing\u003c\/li\u003e\n\u003cli\u003eRadiation shielding accessories\u003c\/li\u003e\n\u003cli\u003eComplete room installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThat allows us to approach a modular room differently than a manufacturer that only produces wall panels.\u003c\/p\u003e\n\u003cp\u003eWe understand the door, the window, the penetrations, the lead transitions and the installation because those are already core parts of what we do.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eStart With Your Shielding Report\u003c\/h1\u003e\n\u003cp\u003eEvery project begins with the room requirements.\u003c\/p\u003e\n\u003cp\u003eSend us your:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShielding report\u003c\/li\u003e\n\u003cli\u003eArchitectural drawings\u003c\/li\u003e\n\u003cli\u003eEquipment layout\u003c\/li\u003e\n\u003cli\u003eDesired room dimensions\u003c\/li\u003e\n\u003cli\u003eDoor requirements\u003c\/li\u003e\n\u003cli\u003eWindow requirements\u003c\/li\u003e\n\u003cli\u003eElectrical requirements\u003c\/li\u003e\n\u003cli\u003eHVAC requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOur team can review the project and develop a complete modular room package around the required radiation shielding.\u003c\/p\u003e\n\u003ch3\u003eNeed a Complete Modular X-Ray Room?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLead Glass Pro can provide the room, shielding components and installation as one coordinated package.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch3\u003eWhat is a modular X-ray room?\u003c\/h3\u003e\n\u003cp\u003eA modular X-ray room is a prefabricated radiation shielding enclosure manufactured from factory-built structural wall, ceiling, door and window assemblies. The system is assembled at the project location to create a complete radiation-shielded imaging room.\u003c\/p\u003e\n\u003ch3\u003eAre modular X-ray rooms lead lined?\u003c\/h3\u003e\n\u003cp\u003eThey can be. The required shielding material and lead equivalency should be determined by the project's radiation shielding report. Lead Glass Pro manufactures the room around those requirements.\u003c\/p\u003e\n\u003ch3\u003eHow much lead does an X-ray room require?\u003c\/h3\u003e\n\u003cp\u003eThere is no standard lead thickness that is appropriate for every X-ray room. Shielding requirements depend on the imaging equipment, workload, room configuration, adjacent occupancy and other factors evaluated by the project's qualified shielding professional.\u003c\/p\u003e\n\u003ch3\u003eCan the ceiling be radiation shielded?\u003c\/h3\u003e\n\u003cp\u003eYes. Shielding can be incorporated into the modular ceiling when required by the shielding report.\u003c\/p\u003e\n\u003ch3\u003eCan the floor be shielded?\u003c\/h3\u003e\n\u003cp\u003eYes. Sheet lead or another specified shielding system can be incorporated into the floor assembly when shielding below the room is required.\u003c\/p\u003e\n\u003ch3\u003eAre electrical outlets included?\u003c\/h3\u003e\n\u003cp\u003eElectrical locations, lighting, controls, warning lights, data connections and equipment wiring provisions can be incorporated into the room configuration.\u003c\/p\u003e\n\u003ch3\u003eHow are X-ray equipment cables passed through the wall?\u003c\/h3\u003e\n\u003cp\u003eDedicated shielded cable penetration assemblies can be incorporated so equipment cables can pass through the barrier without creating an uncontrolled direct radiation path.\u003c\/p\u003e\n\u003ch3\u003eCan HVAC be installed in a modular X-ray room?\u003c\/h3\u003e\n\u003cp\u003eYes. HVAC supply, return and ventilation penetrations can be integrated into the room. Where required, penetrations can incorporate shielding configurations appropriate for the project.\u003c\/p\u003e\n\u003ch3\u003eCan a modular X-ray room be relocated?\u003c\/h3\u003e\n\u003cp\u003eMany modular room configurations can be disassembled and relocated. The ability to relocate a specific room depends on its configuration, utilities and shielding requirements.\u003c\/p\u003e\n\u003ch3\u003eDo you install modular X-ray rooms?\u003c\/h3\u003e\n\u003cp\u003eYes. Lead Glass Pro provides nationwide radiation shielding installation services, including installation of complete modular shielding systems.\u003c\/p\u003e\n\u003ch3\u003eHow much does a modular X-ray room cost?\u003c\/h3\u003e\n\u003cp\u003eModular X-ray rooms are custom systems, and pricing varies considerably based on room size, shielding thickness, doors, windows, finishes, utilities, ceiling and floor shielding, equipment penetrations and installation requirements.\u003c\/p\u003e\n\u003cp\u003eLead Glass Pro provides project-specific quotations after reviewing the room requirements and shielding design.\u003c\/p\u003e\n\u003ch3\u003eDo I need a radiation shielding report before ordering?\u003c\/h3\u003e\n\u003cp\u003eA shielding report is generally the best way to establish the radiation barrier requirements for the room. Lead Glass Pro manufactures the shielding system to the requirements provided for the project.\u003c\/p\u003e","brand":"Lead Glass Pro","offers":[{"title":"Default Title","offer_id":54082135523512,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/7202\/8986\/files\/modular-x-ray-room-prefabricated-radiation-shielding-room-4727242.png?v=1789228746","url":"https:\/\/leadglasspro.com\/products\/modular-x-ray-room","provider":"Lead Glass Pro","version":"1.0","type":"link"}